Use red and black test leads to measure the forward and reverse resistances between any two pins of the two-terminal or three-terminal ceramic filter should be ∞
Release Time:
2022-06-06 21:49
Source:
Measure the forward and reverse resistance between any two pins of the two-terminal or three-terminal ceramic filter with red and black test leads respectively. If the measured resistance value is small or 0Ω, it can be determined that the ceramic filter is damaged. ; It should be noted that if the measured forward and reverse resistances are ∞, it cannot be completely determined that the ceramic filter is in good condition, and the substitution method can be used under amateur conditions.